Xerox Apeos 2350/2150 Error Guidance on 621-400 Data Matching

Visitor 526 0
Overview
The guidance information regarding the matching of 621-400 data in Chapter 4.2 REP 18.1.1 ESS PWB replacement steps of Repair Manual V1 version is incorrect. TI correction is hereby issued.
Content
Scenario 1: When replacing the ESS PWB
Error message: 621-400:2
Correct information: 621-400:1

Scenario 2: When replacing EEP-ROM
Error message: 621-400:1
Correct information: 621-400:2
Screenshot of Error Information
Scenario 1: When replacing the ESS PWB


Screenshot of Error Information
Scenario 2: When replacing EEP-ROM

Tags: #621-400 #2350 #2150