Xerox Apeos 2150,2350 fault code 041-347

Visitor 354 0
Xerox Apeos 2150,2350 fault code 041-347
The communication between BSS and MCU failed, and no ACK was received from ESS after the specified number of retries.
Reason/Handling
1. Open circuit, short circuit, and poor contact of the flat cable between MCU Pll'B (J300) and ESS PWB (SJ29).
If no problems are found during persistence, replace the following parts one by one.
However, please check for any malfunctions and conduct inspections every time the parts are replaced.
Put back the parts that are not problematic.
  • MCU PWB(PL 18. 1)
  • ESS PWB (PL 18. 1)

The suggestion is to update the latest firmware to solve this problem

Tags: #041-347 #2150 #2350