Fault phenomenon: There are many scattered dark spots on the blue or colored Halftones, with spot sizes ranging from approximately 1mm to 2mm. If you observe carefully, there will be black carrier particles in the center of most spots. Cause of the failure: Based on the machines that currently have the most frequent occurrence of this problem, the first solution is to replace the black drum. Further testing revealed that the root cause was the black charging electrode. It was also found that the installation direction of the black charging grid on the on-site machine was incorrect. Solution: Replace the black charging electrode directly. Note: Dark spots appear on the blue or color Halftone, but the reason is due to black charging issues. Please pay attention to this on-site engineer. At present, it has not been tested whether cleaning the mesh can help solve the problem. It was found on site that even with brand new black drums or charging grids, there are still a small amount of slight dark spots on the blue Halftone, but they basically meet the customer's requirements and are difficult to show in their work. |
331
0
Address of this article:https://073868.com/post/2596.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleXerox 700 DCP cannot print online normally through driver
NextXerox 700DCP/700i DCP Printing High Coverage Images with Unfixed IN/OUT Board