After troubleshooting and disassembling to restore, it continues to report C1181 Fault phenomenon, causes, and principles: 1. I began to suspect that there was an error in the recovery process after disassembly, so I removed and reinstalled the disassembled parts again, but the fault still persists. 2. By consulting the maintenance manual, the analysis is as follows: Troubleshooting: 1. Considering that this issue is mainly judged by the PS13 status, the PS13 sensor was replaced again, but the fault has not been resolved. 2. After checking the triggering mechanism of PS13 again and comparing it with other normal FS529s, it was found that the one responsible for triggering PS13 is a black gear with a biased center of gravity. If the white gear that meshes with it is disengaged during disassembly, it will rotate counterclockwise by about 70 degrees under the action of gravity. This phenomenon is very difficult to detect during the disassembly process. 3. Due to the fixed meshing position between this trigger gear and the white gear, if the position of the trigger gear is not manually adjusted to correctly mesh with the white gear during recovery, it will inevitably continue to report C1181. Link: https://pan.baidu.com/s/1ni1KFtikTOPStwmwVa4_ag Extraction code: ugoc |
308
0
Address of this article:https://073868.com/post/2410.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleKe Mei C220 output image abnormal printing has color lines
NextThe black copy of Ke Mei C280 is weak, with codes C5501 and C3921