Xerox DC8000/8000AP fixing pressure adjustment

Visitor 348 0
DC2060/6060/8000/8000AP
Fault phenomenon:
Fixing is not strong or there is an obvious watermark


Cause of the failure:
Wrong fixing pressure adjustment


Solution:
The pressure adjustment of fixing includes two aspects:
1. Fuser Nip Adjustment
2. Fuser Pad Spring Adjustment
As shown in the above figure, on the test page of our DC701, there are two imprints, one thin and one thick. Among them, the thin one corresponds to Fuser Nip, and the width of this embossing shows the size of the fixing pressure, which directly determines the fixing fastness. The thick one corresponds to Fuser Pad Spring. The width of this embossing shows the contact width between Fuser Pad and the heat roller, which will affect the fixing watermark, etc.
The width of the thin strip is 4.1mm ± 0.2mm, and the in-out is uniform.


For the width of the thick bar, there is no strict limit in the manual, generally about 15mm, in-out uniform.
The thin strip corresponds to the spring away from the direction of the pressing belt. The height of this spring should be 36mm-38mm. The principle of adjustment is: make appropriate fine adjustments within this height range according to the width of the thin strip, and the in-out spring height must be consistent.


The thick bar corresponds to the spring closer to the belt. The height of this spring should be 42mm. The adjustment principle is: in-out spring height must be consistent, height 42mm.
After adjusting according to the above adjustment principle, if there is still a problem with the test page of DC701, you should look for the problem on the parts or mechanical structure.
Link: https://pan.baidu.com/s/1Fcc24kWnHcHSfqiw8Pu5Fw
Extraction code: ms3g

Tags: #8000AP #Fixing pressure #C8000