Content: Machine output copy with black bottom ash Execution Maxsetup Abnormal value found for DC933 K Vadcs (VADCS -- the target potential value after ADC Target patch is applied to the drum, which is measured by ESV sensor. Except that the measured value of K is slightly larger than VMS, the measured values of the other three colors should be basically the same as VMS) Check the ESV of K found that the position is wrong after correct installation The value of DC933 K Vadcs is normal Bottom ash failure disappears after test printing Link: https://pan.baidu.com/s/19px0zCC32DIG4JDtGsvGmA Extraction code: dxvx |
Tags: #C8000 #bottom ash