Subject: Code 27-315 appears when the server sends files to print after initializing SYS Content: IOT printing is normal after initializing SYS NVM However, when the server sends a file to print, the machine directly appears 027-315 DFE Logic Fail DFE Command This error is caused by the following two NVM values being abnormal after initializing SYS NVM 720-958 sys behavior switch 720-263 software Ver mismatch BYPASS After changing NVM 720-958-> 3 720-263-> 1, the test printing is normal. The CSV file to be imported after IOT and SYS initialization can be found under the firmware of each version. Please import the corresponding CSV file after IOT or SYS initialization is executed. Take 3.6.86 as an example. CSV can be found through the following path (the two NVM changed above can be seen after opening with Notepad) Saroma_V3.6.86J\V3.6.86\2.UpgradeObject\V3.06.86\1.NVMFile\Sys\1.NVM_write_file_after_initialization_for_V3.6.01\V3.6.01_SysNVMWrite.csv \Saroma_V3.6.86J\V3.6.86\2.UpgradeObject\V3.06.86\1.NVMFile\IOT\1.NVM_write_file_after_initialization_for_V3.6.01\V3.6.01_NVMWrite.csv |
306
0
Address of this article:https://073868.com/post/2323.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleXerox C800P has 072-101 code second carton jam