Kemei C300i/360i produces abnormal noise during startup

Visitor 308 0
Remove the fixing device for inspection: there is slight wear on the pressing gear of the fixing pressure roller
Check the fixing drive: The pressure roller and pressure gear on the frame also have slight wear
Preliminary determination is that the abnormal noise is caused by insufficient gear meshing during the pressurization of the fixing pressure roller
Check the rack and find that the rack is deformed. Please refer to the attached diagram for details
Rack deformation is considered to be caused by external forces
Possible external forces during storage or transportation

[supplement]]
① The copier makes a rattling noise when turned on, and the fixing pressure roller has not reached its working position
② When the frame deforms, there is a gap of 1-2mm between the fixing pressure gear and the driving pressure gear.
③ Not only the fixing part is deformed, but also the power supply part is deformed
④ Rack shaping requires the removal of power boards, motherboards, fixing drivers, developing systems, etc.
⑤ After the plastic surgery is completed, reinstall and troubleshoot. Link: https://pan.baidu.com/s/1YU0gTZvKXdsoh77ISnP50Q
Extraction Code: ezlc

Tags: #C300i #C360i #Fixing pressure roller #Abnormal noise