2.1. Bizhub 367 series release (special program feature version 4.2 GC2-V1)The files and checksum are as follows| Program name | filename | Checksum | Note | | MFP card version | A7AH0Y0-F000-GC2-V1 |
|
| | MFP Controller Based on Linux | Linux-3.10.40 | 735B |
| | MFP controller kernel program | A7AH0Y0-1C00-GC2-E2 | 1A12 |
| | MFP controller subroutine | A7AH0Y0-1F00-G00-U0 | 7200 |
| | MFP controller | A7AH0Y0-0100-GC2-U8 | 7977 |
| | MFP controller system | A7AH0Y0-1000-GC2-U8 |
|
| | MFP Controller Print Controller | A7AH0Y0-3000-GC2-U2 |
|
| | MFP controller printing controller font | A7AH0Y0-3F00-G00-U1 |
|
| | MFP Controller Print Controller Demo Page | A7AH0Y0-3E00-G00-00 |
|
| | Image reader controller | A7AH0Y0-8600-G00-F1 |
|
| | MFP Controller MIO | A7AH0Y0-5000-G11-C0 |
|
| | MFP Controller PIC | A7AH0Y0-8200-G00-G0 |
|
| | MFP controller thread image parameters | A7AH0Y0-8B00-G00-02 |
| Old CCD | | MFP controller thread image parameters | A7AH0Y0-8B01-G00-02 |
| New CCD | | MFP Controller PIC Image Parameters | A7AH0Y0-8A00-G00-01 |
| Old CCD | | MFP Controller PIC Image Parameters | A7AH0Y0-8A01-G00-01 |
| New CCD | | MFP Controller IR Image Parameters | A7AH0Y0-8C00-G00-30 |
| Old CCD | | MFP Controller IR Image Parameters | A7AH0Y0-8C01-G00-30 |
| New CCD | | Fax circuit board controller | A8790Y0-4000-GD4-19 | 76C1 |
| | Operation panel information data | A7AH0Y0-8100-GC2-U8 | A4D5 |
| | ADF | A7V70Y0-0024-G00-35 | 17CA |
| | Machine controller | A7AH0Y0-0200-G10-16 | 5BED |
| | Machine controller printer | A7AH0Y0-0220-G10-14 | 88B4 |
| | Machine controller medium | A7AH0Y0-0230-G10-00 | CED2 |
| | Machine Controller IO | A7AH0Y0-0240-G10-00 | DCB2 |
| | Machine controller scanner | A7AH0Y0-0300-G10-06 | 50FC |
| | Paper Discharge Processor (FS-533) | A2YU0Y0-0071-G10-03 | B0E1 |
| | Paper Discharge Processor (FS-534) | A3EP0Y0-0071-G10-05 | 7C69 |
| | Separators (JS-506) | A2YV0Y0-0070-G00-01 | B1E3 |
| | SD | A3ER0Y0-0071-G00-10 | E95B |
| | Integrated printer driver version | 5-4.2-0-GC2-V1 |
|
| 2.2. modify project2.2.1 Solved ProblemsThe firmware addresses the following issues. When using PaperCut on an MFP, C-E301. [ERBEU_1700897807] may occasionally appearWhen the MFP is connected to Fiery (IC-416/IC-418), if Fiery's power is OFF, the MFP does not switch to [Low Power Mode/Sleep Mode] [ERBJOS1800905819]Even if DipSW number 48 bit 5 is enabled, the function of reducing LDAP search time does not work [ERBUS_1800902773]4. When the user selects a paper tray and restarts the print job when an [unmatched paper] error occurs, the print job remains as [Printing] [ERBJTS1700894958]5. The default scanning settings of the MFP have not been applied to the Scan-D application [ERBEU_1700898165]6. The 'Topology List Version' on the topology machine does not match the 'Topology List Version' on the restarted client machine [ERBJOS1800903057]7. After the user logs in using an IC card through the enhanced server authentication browser authentication function, if the user places the same IC card again, the MFP will unexpectedly execute automatic logout/login [ERBAU_1800902157]8. The panel locks during self registration [ERBJ__1800905288]If a job is repeatedly executed on an IWS application, the job becomes unable to be executed [ERBJSL1800906006]10. In specific customer environments, disabled users cannot be removed from PSES [ERBJSL1800904556]11. Due to the SoftDipSW value, the panel log appears garbled, making it impossible to analyze the log [ERBJ__1800905449]If the file name on the searchable PDF is changed after enabling Adjust Rotation, the Adjust Rotation setting becomes unavailable [ERBEU_1800904346]If a PC print job is executed while the MFP is in low-power mode, the control panel may light up and display the message "A warning has occurred ). [ERBJOS1800903088]When a level B fault occurs, logs cannot be obtained through automatic log storage on the hard drive *When a level B fault occurs, the availability of the fault reset time function can be switched through the automatic cancellation function (Position 3)Soft switch number 104 0x00: Perform fault reset without waiting for log completion to be stored on hard drive (default)Soft switch number 104 0x08: Perform a fault reset after completing the storage of logs to the hard diskWhen performing test printing on Dell Wyse D10D (Linux based Thin Client), the output is blank [ERBUS_1800906618] *The byte count of the data file on the LPR command is specified as 0 to ensure the availability of the MFP's data receiving functionSoft switch number 107 0x00: If the byte count is specified as 0, the MFP does not receive data (Default)Soft switch number 107 0x08: Even if the byte count is specified as 0, the MFP can still receive dataWhen the MFP is restored from low-power mode, if IC-416/IC-418 is installed on the MFP, the message "Unable to detect the connection to the controller." will be displayed on the MFP control panel ). [ERBJ__1800906777]17. In the environment connected to IC-418, the MFP restarts instead of recovering from energy-saving mode, and then records C-FA14 (detailed code: 0x60FC) after the restart. [ERBBT1800906382]Even if the phone/fax switch of fax firmware G00-19/GD1-19 is set to ON and the voice response is set to OFF, the phone connected to the MFP always ringsWhen printing Yahoo's homepage through a web browser, the message "Preparing for printing" keeps appearingWhen using the automatic log storage function of the hard disk during a malfunction, the MFP may not restart immediately after completing the log storageIf a job is repeatedly executed on the IWS application, the MFP crashes [ERBJSL1800906006]22. When printing a specific PDF file to A4 size by specifying a reduced size in PJL, the position of the output image shifts downwards [ERBJSL1800907252]If you restart the MFP after registering the authentication browser application and then change the [Web Browser Usage Settings] to [Disable], the MFP will remain displaying the activation screen [ERBUS_1800907675]When starting the IWS application, a timeout may occur [ERBJSL1800906023]When using the IWS application, a 503 error occurred and processing may not continue [ERBJSL1800906006]26. Unable to register devices on the device registration screen of Google Cloud Print Setup [ERBEU_1700893318]If the original letter size is scanned as a mixed original and designated as a PDF file type, the letter size becomes 8.5x10.97 inches [ERBUS_1800905522]Even if other original documents are detected on the manuscript table, it may not be possible to scan the original documents from ADF [ERBJOS1800906032]When installing firmware version 4.2, the settings for TLS1.0 and SSL3.0 become OFF30. J1 * -40. [ERBJTK1700898491]After updating to version G00-U8, the copy component counter will not be displayed on the counter list [ERBJOS1800907439]32. The PDF size created by scanning becomes A3: 419.8 x 296.7, A4: 209.9 x 296.7. [ERBUS_1800905522]When printing a specific PDF file directly, the job is not printed [ERBUS_1800907875]34. Fault code C-E301 (0xC4AB/0xB4AB) may occur in the environment where PeperCut is used. [ERBUS_1800904964]When using the external storage backup function to rewrite the hard disk encryption settings, the message "Operating remotely. Please do not turn off the power." is displayed Please do not turn off the power )And the MFP may not be operational [QUBJ__1800908204]When printing a specific PS file directly, output an error page [ERBEU_1800908458]When executing SafeQ printing, the data indicator light remains flashing and the job has not been printed [ERBJTS1700894958]38. The G00-U8 firmware is unable to display the screen correctly [QUBEU_1800908703]When J3003 appears, distinguish the paper jam in the transfer belt from the paper jam in the fixing unitWhen receiving a fax in the modem dial in setting environment, the phone connected to the MFP will ring [ERBJTK1800909196]41. Solution to Wi Fi vulnerabilities The countermeasures to add UK-212 and UK-215/216 have failedAfter turning on the main power, even if the buttons are pressed, the soft buttons in the touch panel area, except for the hard buttons, do not respond*For detailed information, please refer to TABT1800928ENEven if A3 size paper is loaded into the hand paper box, the paper size is displayed as A4 sizeAfter pulling out and inserting the paper box, the copying operation will not start even if the start button is pressedIf the Receive Signal Detection Mode is set to "Times" and the MFP is in power-saving mode, the MFP may not receive incoming faxes [ERMura1800911065]When turning off and then on the main power switch, it may not be possible to print by connecting a USB flash drive *This firmware covers all resolved issues on GC1-U8 or earlier versions 2.2.2 CustomizationThis firmware supports the following customizations<Note>-AtCSESIn the requested customer environment,Can guarantee the following custom operations.When transferring this customization to other customers, please be responsible for verifying the effectiveness of the OC (operating company) to meet their requirements*When more support is needed for effectiveness verification,Please follow the usual procedureCSESPublish a report. [New supported content]1)enabledDipSW 231(position0)time,'Unsupervised homework'It will also be automatically deleted as a job in the job deletion settings(Set mode4time).[ERBUS_1700901099][Usage Summary]Delete job when it is processed by a third-party application backend: OutputManager follows the deletion criteria set in DipSW 231 (bit 0) settings [Custom]#When DipSW number 231 (bit 0) is enabled and [Mode 4] (mode 4) is set in the job deletion settings, 'unsupported job' will be added to the job type to be deleted#The DipSW number 231 (bit 0) feature will also support 'authentication browser applications'#The warning screen displayed when deleting a job through DipSW 231 (bit 0) function will be hidden [DipSW Information]When Dip SW number 231 (bit 0) is enabled and [Mode 4] (mode 4) is set in the job deletion settings (bit 7), the function of [job without authentication design] is included in the job types to be deletedSoft switch number 231 0x00: Not used (default)Soft switch number 231 0x80: UseThe function of not displaying the "History Confirmation Warning" when deleting a job through the DipSw number 231 bit 0 functionSoft switch number 239 0x00: Not used (default)Soft switch number 239 0x01: Use [Setting Information]This function can be enabled through DipSW number 231: bit 7, DipSW number 239: bit 0In addition, it is necessary to enable DipSW number 231 bit 0 in any of the above DipSW [Note]The function of deleting the target job when a specific error occurs (Position 0)Soft switch number 231 0x00: Not used (default)Soft switch number 231 0x01: Use 2)After scanning and transmitting,Keep specific destinations and cancel scanning settings.[ERBEU_1800904477][Usage Summary]In most cases, various original documents are set to the same destination with different scanning settings in the client's workflowHowever, the current job reset settings only have options "Reset All", "Reset Destination Only", and "Confirm with User"The customer hopes to improve work efficiency by using the "Reset Settings Only" feature in the job reset settings[Custom]By enabling DipSW, the function of retaining specific destinations and canceling scan settings after scanning transfer can be usedIn this case, the settings on [Job Reset Setting]>[Next Job]>[Reset Data After Job] will be ignored[DipSW Information]After scanning and transmitting, keep the specific destination and cancel the scanning settings (Position 1)DipSW ID 239 0x00: Disabled (default)DipSW ID 239 0x02: Enable[Setting Information]This function can be enabled through DipSW number 239 digit 1 3)Scan to BeltDNSThe host nameURL.[ERBEU_1700900086][Usage Summary]The customer uses an SSL certificate from their own CA on the device (bizhub)In this case, the URL used for scanning must contain a common name(SSL Certificate Issuing Object)However, the device (bizhub) sends a URL with only an IP address (non generic name)Therefore, when scanning to a URL via HTTPS, the client will receive a certificate error[Custom]Please replace the IP address with the DNS host name of the MFP for the URL mentioned in the email used for scanning to the URL[DipSW Information]Switch the 'IP address' to' DNS host 'to access the scan to URL feature (bit 4) notification email URLSoft switch number 234 0x00: Not used (default)Soft switch number 234 0x10: Use[Setting Information]The DipSW settings shown above are required to enable this feature No other settings are required 4)visit"Forward TX Setting"(ForwardTXSettings)Without entering the administrator password[ERBJSL1700900574][Usage Summary]The customer opens/closes the fax transmission function and forwards faxes multiple times a dayEvery time, it is necessary to enter a password to enter the administrator settings, which is time-consuming and laborious[Custom]-Create a shortcut for 'Forward TX Setting' in the top menu-When selecting the shortcut (Forward TX Setting), it will switch to "Forward TX Setting" without entering a password[DipSW Information]Create a shortcut key to switch to 'Forward TX Setting' without entering the administrator password (Position 5)Soft switch number 236 0x00: Not used (default)Soft switch number 236 0x20: Use[Setting Information]The DipSW settings shown above are required to enable this feature No other settings are required 5)Request to enhance the image log transmission function[ERAOAC1700898301][Usage Summary]The transmission of image logs may fail due to network environmental factors. Please enable the specification of transmission time and reduce the size of image log files[Custom](1) You can set the image log transmission time-Real time-Specific days and specific times(Specific days: Monday/Tuesday/Wednesday/Thursday/Friday/Saturday/Sunday)(Specific time: 0-24 hours)(2) You can choose the resolution of the image log- 100dpi- 200dpi- 300dpi- 600dpi(3) You can choose the page for image logs-All pages-Odd pages-Even numbered pages-Start and End Pages(4) The image log transmission function can be set through PSWC[DipSW Information]Enhance image log transmission function (bit 5)DipSW ID 204 0x00: Disabled (default)DipSW ID 204 0x20: Enable[Setting Information]These DipSW settings are required to use the enhanced image log shipping featureDipSW number 63 digits 0: Enable image log transfer functionDipSW number 204 digits 5: Enhance image log transmission function 6)SupportDHCPRequest options81.[ERBEU_1800908252][Usage Summary]The DNS records of the DNS server are not updated from DHCP clients (MFPs not in the active directory)This situation occurs in the AD integrated environment of Windows, where DNS behavior updates are set to 'secure only'[Custom]Add support for DHCP request option 81[DipSW Information]You can set the function to support DHCP option 81 (bit 3)DipSw ID 219 0x00: Disabled (default)DipSw ID 219 0x08: Enable[Setting Information]This feature can be enabled through DipSW number 219 digit 3 7)ThroughIWSExecute homework using voice commands(andBFofEVASystem related) [ERBEU_1700900981][Usage Summary]We need to provide a solution for people with visual impairmentsTherefore, we need to use an external supplier's voice authentication system (EVA system)We hope to issue instructions from the EVA system through IWS, but the IWS application in the MFP cannot execute jobs externally[Custom]-Use an external supplier's voice authentication system (EVA system) and customize the firmware, allowing commands to be sent from the EVA system (via IWS) to perform copying and scanningSpecifically, we customize the IWS application in the MFP to execute jobs after receiving instructions from external applications-Change the ringtone for inserting and removing USB so that visually impaired individuals can distinguish between them[DipSW Information]1) Function setting for executing tasks through IWS based on voice commands (bit 6):Soft switch number 236 0x00: Disabled (default)Soft switch number 236 0x40: enabled2) Change the function settings for inserting/removing USB notification ringtones (bit 7):Soft switch number 236 0x00: Disabled (default)Soft switch number 236 0x80: enabled[Setting Information]To enable this feature, DipSW number 236 bits 6 and 7 need to be set*Note: DiPSW 236 bit 6 and bit 7 can be set separately[Restrictions]1) DipSW 236 bit 6 (supports voice operation)-Designed solely for association with EVA systems; Therefore, it cannot be combined with other systems for use2) DipSW 236 bit 7 (supports changing USB ringtone)-You need to execute commands from the terminal to install these ringtones (notifying USB insertion/removal) For detailed information, please refer to [Customization No.7 (ERBEU_1700900981) \ Now to install the USB Sound File. xlsx]-Due to the use of voice data customization in this project, the voice guide function cannot be used
8)Enable fax redialing feature in the splitter settings environment.[ERBUS_1700899312][Usage Summary]When using multiple fax devices on a single line with a telephone splitter, the following issues may occurWhen the line is used by equipment from other companies, KM equipment cannot redial and corresponding fax transmission failure occurs[Custom]Even when other companies' devices use lines to send faxes, KM devices can still redial faxes[Details]When other companies use fax lines to send faxes before KM devices, T-81 (dial tone detection failure) appearsThe control of KM equipment is as follows:When checking T-81, KM equipment redials, but checks if the line is disconnected, and reads error code T-80 (not redialed) when disconnection is detected When using a splitter, the fax line will be identified as disconnected based on the order in which the device is connected to the fax lineTherefore, enabling this customization can stop checking if the circuit is disconnected[DipSW Information]When T-81 (dial tone detection failure) occurs, the device redials without checking if the line is disconnected (Position 2)DipSW number 237 0x00: Do not redial fax (default)DipSW number 237 0x04: Redial fax[Setting Information]The DipSW settings shown above are required to enable this featureThe fax redial settings need to be pre configured according to the following stepsAdministrator Settings ->Fax Settings ->Line Parameter Setting 9)Custom firmware has added interfaces,Therefore, it is possible toRDTConfigure Scan Default Settings.[ERBEU_1700890735][Usage Summary]In the current Remote Deployment Tool (RDT), color, file type, and resolution can only be set as default scanning settings on the machine The customer wishes to set "the best scanning settings suitable for all original documents" as the default setting for all machines Due to the application of these settings through RDT, it is necessary to customize the added interfaces[Custom]The custom firmware has added interfaces, so default scanning settings can be configured on RDT[DipSW Information]DipSW number 238: bit 0Hex: 0x00 disabled (default)Hex: 0x01 enabled: Added interface to configure scan default settings on RDT[Setting Information]When using this function, please set DipSW number 238: bit 0[Note]This feature is supported by RDT V.1.3.00110 or higher versions 10) When logging in through an IC card, there is no longer a need to perform the re authentication steps required for USB printing [ERBEU_1700897458][Usage Summary]When logging in through an IC card, the username and password are not saved on the MFP, so a screen asking for username and password input will be displayed when printing from Pendrive[Custom]When logging in through an IC card, the username and password are not saved on the MFP, so a screen asking for username and password input will be displayed when printing from Pendrive[DipSW Information]DipSW Number 209 (Position 5)Hex: 0x00 disabled (default)Hex: 0x20 enabled[Setting Information]When using this function, please set DipSW number 209 to position 5Link: https://pan.baidu.com/s/1VshoWvN_tfBvVnd5rdQNvw Extraction code: qaw7
|