Symptoms: The MPC2503 machine does not display the message "Fixing unit installation error" when the screen is displayed. Reason: 1. Fixing unit error; 2. Poor wire harness contact; 3. Bad motherboard and power board; 4. Poor paper transfer IO board. On-site implementation measures: 1. Reinstall the new fixing unit, and the fault remains; 2. Plug and unplug the fixing unit harness again, and the fault remains; 3. Replace the motherboard and power supply board in turn; The fault remains; 4. Check the point-to-point wiring diagram and find that the fixing unit is associated with the machine paper transfer IO board,
Solution Replace the paper transfer IOB, the fault disappears, and the test machine is normal. |
Tags: #IO board #C2503 #Fixing Unit