Symptoms SC220 (laser synchronization detection error) occurred during MP7503SP operation. The LD unit, laser synchronization detector, BCU board, prism motor, and drive board were replaced, but the fault persisted. Cause analysis After downloading laser parameters through SP2110-005, the fault code still appears. When confirming the occurrence of the fault with the on-site engineer, it was found that the fault occurred after the engineer disassembled, cleaned, and maintained the PCU unit (drum frame). Therefore, the PCU unit was inspected(Drum stand)The metal sheet of the drum charging terminal was found to be deformed, causing poor grounding and affecting the laser synchronous detection error.
Solution Rectify and install the charging terminal again. |
337
0
Address of this article:https://073868.com/post/1358.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh C6502 experiences paper jam (code 152) or paper damage