If the machine reports code 552-02 and uses 5-810 to restore it, there is a chance of success, but it still jumps after using dozens of pictures. Check that the thermistor fuse is not damaged, and use code sc1-106 to find that the temperature is too low. Replace the infrared temperature sensor unit and find that it is still good and sometimes bad. Replacing the fixing component is ineffective.By checking the input voltage through a point-to-point graph, it was found that the PSU (AC controller board) sometimes did not input to the fixing circuit, and the 220 voltage input to the PSU board was normal. After replacing the PSU board, the machine returned to normal.
|