Ricoh Ricoh IM 7000/IM 8000/IM 9000 About Code SC670/SC672 Troubleshooting

Visitor 426 0
SC670 (engine startup error) report appears

Reason
The engine board was accidentally reset and will not restart.
The order of occurrence is SC670-03>04>05>01>02

Solution


SC672 (control board startup error) report appears
Overview
The intelligent operation panel communicates with the controller through USB data cables and wiring harnesses. When a communication failure is detected between the intelligent operation panel and the controller, SC672 will be displayed.
If SC672 appears when the smart operation panel is closed, please follow this step to resolve the issue.

Block diagram of intelligent operation panel
[A] : USB data cable
[B] : Wiring harness
[C]: DIMM
[D]: LED
[E] : Fixing


SCReason
SC672-00Communication error between the operation panel and controller after the machine is powered on
SC672-10Communication error (reception) between the operation panel and controller after the machine is powered on
SC672-11Communication error (sending) between the operation panel and controller after the machine is powered on
SC672-12Communication error between the operation panel and controller after normal startup
SC672-13Due to the aforementioned reasons(-Communication errors between the operation panel and controller have been detected for reasons other than 00, -10, -11, and -12
SC672-99Software for the operation panel(OCS unexpectedly shut down
Flowchart for identifying the cause of the problem
Flowchart for identifying the cause of SC672 when it occurs





Flowchart for determining the cause of the problem when the control panel is not lit up




Solution
Before replacing components, please make sure to turn off the main power and unplug the power plug from the socket to check if the problem will occur again
Before replacing the circuit board, cables, and control panel, please check if the problem reoccurs

Disconnect, reconnect, and replace USB data cable
1. Reconnect both ends of the USB data cable and check if the problem still exists
If the problem still exists, please determine the cause of the problem according to the flowchart
3. For information on how to remove and reconnect PCBs, control panels, and data cables, please refer to Chapter 4 "Replacement and Adjustment"

Replace DIMM
1. Open the DIMM slot and remove the DIMM

2. Lower the lock on the side of the DIMM slot outward and insert a new DIMM. Ensure that the DIMM is inserted vertically into the slot
3. Keep inserting the DIMM until it makes a clicking sound
DIMM replacement steps (taken from the manufacturer's specification sheet)


DIMM locked status (A: unlocked, B: locked)


LED/POSTCODE display
1. .POSTCODE CodeTurn on the power or computer from STR When the status is restored, it will display BIOS Self diagnostic codeBIOS The indicator light after completion
POSTCODE1,2,3,4,5,6light up
POSTCODE7light up
POSTCODE8flicker
If DIMM Loose connection or BIOS Error, power on self-test code 7 Not flashing, some or all indicator lights are onEquipment status and LED instructions
StatusLED

BIOS/OS LED (red)POST CODE LED (red)
Normal (at the startup)UndefinedUndefined
Normal(Waiting)Slowly flashing(Every 1 second)Slowly flashing (Every 1 second)
DIMM errorClosePart or all of the lights are on
Control board error(BIOS error)CloseAll lights are on
Control board errorSlowly flashing (Every 1 second)POST CODE8Slowly flashing (Every 1 second)
Fig.1: LED area


Fig.2: Normal (waiting) (POSTCODE_8 and BIOS/OS LEDs flash every 1 second)


Fig. 3: Error Status[A]: LEDs 1, 3, 5, and 7 light up[B] LEDs 1 to 8 are all lit up



Check the fixing process
Check the voltage of the output port (operation panel)Fig.4: Fixing