Ricoh PRO C651/C751 Copy Shallow Report Code SC402

Visitor 376 0
Model: RICOH PRO C651/C751

Symptom: The printed copy of YMC is particularly shallow, and in severe cases, the code SC402 magenta GAMA value is not within the normal range. The magenta value of SP3630 is 0.27, * 0.52, cyan 0.63, and black 1.26.


Reason: The powder pump of the YMC powder supply unit has malfunctioned, resulting in the inability to dispense powder. The concentration of toner in the developing chamber is decreasing, and the GAMA value is also decreasing.
Solution:

1. Confirm if the TE sensor is faulty. SP5803-021 displays 10001111. The black TE sensor detects powder, while the other three colors detect no powder. Remove the TE sensor from the powder supply unit and confirm that it is functioning properly.
2. Maintenance mode: SP5805-061 (C), SP5805-062 (M), SP5805-063 (Y) detect that the powder bottle motor is working normally. SP5805-066 (C), SP5805-067 (M), SP5805-068 (Y) detect the action of the powder pump clutch (audible clutch sound). SP5805-071 (C), SP5805-072 (M), SP5805-073 (Y) detect that the powder clutch is operating (the sound of the clutch can be heard). SP5804-091 detects that the powder motor is working normally. When the powder motor is working, the powder pump clutch is in the ON state, and the toner enters the powder hopper of the powder supply unit from the toner bottle. When the toner motor is working, the toner clutch is in the ON state, and the toner enters the developing chamber from the toner hopper of the toner supply unit.
3. Based on the detection results of the TE sensor and actual inspection (by removing the TE sensor), it was found that there is no toner in the YMC powder hopper. Set the powder pump clutch of SP5805-066 (C), SP5805-067 (M), and SP5805-068 (Y) to the ON state, and set the powder motor of SP5804-091 to run for 10 seconds in the ON state. Check that SP5803-021 displays 10001111, and during actual inspection (by removing the TE sensor), there is no toner in the powder hopper, confirming the fault of the YMC powder pump.
4. Replace the YMC powder pump with a new one and manually replenish the powder during diagnosis. Check that SP5803-021 displays 11111111, indicating that TE sensor has detected toner in the powder hopper. The GAMA values in SP3630 are K 1.26, C 1.08, M 1.09, and Y 1.09, which are within the normal range.
5. Due to powder dispensing malfunction, the machine will lock the original powder bottle, so a new YMC powder bottle needs to be replaced. When the TE sensor detects no powder, it will automatically turn on the powder pump to dispense powder.
Attention: When using SP code to refill the powder pump into the powder hopper during diagnosis, do not exceed 10 seconds, otherwise it may cause the powder hopper to be filled with toner.

Tags: #C651 #C751 #Light color #Pink bottle #SC402