The machine replaced the yellow toner and printed several yellow test pages, which prompted for replacement. Check the rotation of the developing chamber gear and the lower powder chamber to ensure that the test can rotate. Enter maintenance mode to check the 3210 yellow concentration value of 3.2, which is relatively high. Initialize the carrier 3030 once, and after doing 3011, if the concentration value decreases, test again for about 100 pages. There is no prompt to replace the toner bottle.