Symptoms: The machine often reports a fault code SC381-02 during use or when it is in a state of long-term standby and wake-up; On-site implementation measures: 1. Check and clean the potential sensor and related sensor connectors, and test that the fault still exists; 2. Check the fuses on the potential sensor board and AC control board, both tested normal; 3. Replace the potential sensor, but the fault persists; 4. Upon inspecting the customer's usage environment, it was found that the customer's machine was using an old and worn-out cable tray with a high-power heater attached. Therefore, it is recommended to replace the machine cable tray and request one cable tray for each machine. After replacing the cable tray, the fault was resolved through testing and the machine was tested and found to be functioning normally. Solution Replace the machine towing board and test run it normally. |
275
0
Address of this article:https://073868.com/post/1218.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh MPC6502, 8002 appear SC486 code
NextRicoh MP2555SP/MP3055SP/MP3555SP Immediate Replacement of Fixing Belt Unit