Symptoms When MPC6503SP color printing and copying, the image has a full red background, and black and white operations are normal. Maintenance According to the fault sample, it is determined that the red PCU has a poor charging fault, but the fault still persists after replacing the PCU unit. 2. Swap the two charging high-voltage boards for testing, and if the fault persists, confirm that the charging high-voltage boards are functioning properly. 3. Misconnect the PCU charging plug of the high-voltage charging board for detection. The fault changes from a red background to a black background, indicating that the charging control signal is incorrect and the IOB board is faulty. Link: https://pan.baidu.com/s/1I1TqeyXzSg_28DKldxpNGw Extraction code: 9hlb |
Tags: #C6503 #Red background #PCU charging #High pressure plate #c8003