Symptoms The MP5055 machine produces gray stripes of about 2CM at the end of the first print of each job on the copied and printed products. Maintenance process 1. By using the method of making cardboard, it was confirmed that the fault occurred before the paper entered the fixing process, and fault stripes had already appeared on the drum; 2. Cleaning the imaging components around the PCDU drum assembly failed to eliminate the malfunction; 3. Attempted to replace the PCDU drum component for testing, but the fault persisted; 4. During the inspection, it was found that the developing bias contact spring on the rack had slight deformation and oxidation; Link: https://pan.baidu.com/s/1Sikjm4iPw03cRuexP9t5RQ Extraction code: s96v |
Tags: #5055 #PCDU #Drum Assembly #Gray stripes #2555