After the motor starts rotating, perform a detection every 100 milliseconds; But no drive detection signal was detected within 2 seconds. Countermeasure 1: Check the connection of the plug (J2002/J2255/J203). 2. Replace the main motor (M1). 3. Replace the DC controller circuit board (UN2). E010 0002 05 Title: The main motor (M1) rotates unstably. When the main motor rotates, perform a detection every 100 milliseconds; However, no driving signal was detected for 5 consecutive times. Countermeasure 1: Check the connection of the plug (J2002/J2255/J203). 2. Replace the main motor (M1). 3. Replace the DC controller circuit board (UN2). E014 0001 05 Title: The fixing motor (M2) rotates unstably. After the motor starts rotating, perform a detection every 100 milliseconds; But no drive detection signal was detected within 2 seconds. Countermeasure 1: Check the connection of the plug (J2001/J203). 2. Replace the fixing motor (M2). 3. Replace the DC controller circuit board (UN2). E014 0002 05 Title Fixing motor (M2) rotates unstably. When the drum motor rotates, a detection is performed every 100 milliseconds; However, no driving signal was detected for 5 consecutive times. Countermeasure 1: Check the connection of the plug (J2001/J203). 1. Replace the fixing motor (M2). 2. Replace the DC controller circuit board (UN2). Link: https://pan.baidu.com/s/1tjBpdNcpWvyIJmDrxqDV1Q Extraction code: vufc |