Symptoms SC672-21 failures occur after the machine is started and during use within the specified time. (Note: A fault occurred after the machine was started in the morning; restarting the machine several times restored normal operation. The customer reported that SC672-21 faults occurred between 8:00 a.m. and 10:00 a.m.) Reason 1) The machine control panel is not good. 2) poor machine operation panel. 3) The wiring harness from the machine operation panel to the control board is defective. 4) Bad machine motherboard BICU 5) poor firmware of the machine. 6) The machine power board and power supply are unstable. Maintenance process On-site maintenance measures: 1) Disassemble and install the connection harness of the operation panel, control board and main board BICU. Firmware upgrade. The machine has been started, but the fault cannot be resolved. 2) Replace the machine's operation panel unit, control board, motherboard BICU and power board. The fault still exists. 3) Replace the machine to use the power environment and add the voltage regulator, and troubleshoot the machine. (Note: After checking, the socket line is connected to multiple electronic products, which causes voltage instability fault. Start the control board system error) Solution Replace the machine to use the power environment and add voltage regulator, the machine is normal. |
Tags: #SC672-21 #Power supply #Control panel #C6000