Reason analysis of MP2001L_2501L_2001SP_2501SP_1813L_2013L 1. Please refer to the MP2001L maintenance manual for the SC120 code reference solution, as shown in the table below.
2. After replacing the entire scanning unit and BICU board, the fault persisted. 3. According to the on-site situation analysis, the exposure light did not light up and the scanning frame did not move during the process of the machine starting up and reporting the SC120 code. Based on this, it is determined that the scanning unit did not provide power and caused a fault code. Further investigation of the power board is required. 4. Replace the power board and eliminate the fault code. Solution Replace the power board. Note: The basic action of turning on the scanning unit is to move the scanning frame to the reference white position, light up the exposure light, and finally return the scanning frame to its original position. Open the cover of the manuscript table to observe the SC code related to startup and scanning. If none of the above actions are taken, first investigate from the power board. |
Tags: #2001L #sc120 #Power board #scanning rack #BICU