The adjustments that must be made after replacing each component and the reference time for each operation are as follows.
Nozzle replacement: 15 minutes (1 nozzle)
1. Thermistor inspection
You can check it in the Service MENU>THERMOSTOR CHK.
2. Nozzle calibration
3. Clear nozzle information
Adjustment time: 25 minutes
Total time: 40 minutes
Ink pad replacement: 10 minutes (4 pieces)
Total time: 10 minutes
Ink car motor replacement: 20 minutes
1. Servo lock check
You can check in MOTOR MENU>SERVO LOCK>S.
2. Aging
It can be done in MOTOR MENU>AGING>SCAN.
3. Motor time clearing
Adjustment time: 5 minutes
Total time: 25 minutes
Stepper motor replacement: 40 minutes
1. Servo lock check
2. Aging
It can be done in MOTOR MENU>AGING>FEED.
3. Inspection of Grating Disk Decoder
4. Motor time clearing
Adjustment time: 6 minutes
Total time: 46 minutes
Grating disk decoder replacement: 10 minutes
1. Inspection of grating disk decoder
Adjustment time: 2 minutes
Total time: 12 minutes
Pump replacement: 10 minutes
1. Pump inspection
2. Pump time clearing
Adjustment time: 2 minutes
Total time: 12 minutes
Motherboard replacement (if Peck is unable to transfer parameters): 35 minutes
1. Battery installation
2. Firmware installation
3. System parameter initialization
4. Time and date settings
Set the date and time in [Service MENU]>[SUB MENU]>[LOCK]. *Set [date] in the order of [year/month/day].
5. IP address setting
Start the machine in service mode and set it in the user menu.
6. Nozzle serial number setting
It can be set in [RINT MENU]>[HEAD RANK].
7. Serial number input
You can set it in [SUB MENU]>[ERIAL NO.].
8. Ink type settings
You can set it in [SUB MENU]>[HANGE INKTYPE].
9. Sensor inspection
It can be done in SENSOR CHECK.
10. Initialization of limit and paper cutter position
11. Adjust the flash spray position according to the serial number.
12. Grating decoder settings
13. Adjustment of paper measuring sensor
14. Nozzle calibration
Only horizontal and bidirectional adjustment are required.
15. Calibration
Adjustment time: 70 minutes
Total time: 105 minutes