Ricoh Pro 8300S,8310S,8320S,8310,8320 Chinese Maintenance Manual

Wrong name
Lamp error (scan) (front)
When the scanning level of the whiteboard or ADF guide is below the specified value, this error will be detected.
main reason
1. The ADF guide plate (white roller) is dirty.
2. Poor connector.
3. The whiteboard is dirty or defective.
4. Poor ADF guide plate (white roller).
5. Poor mirror and optical device.
6. Poor LED board.
7. Poor SBU.
8. BiCU is defective.
9. Poor wiring.
*Condensation inside the scanner unit
Solution
1. The ADF guide plate (white roller) is dirty
Clean the ADF background board.
2. Poor connector.
Reconnect the following connectors:
SBU BiCU wire (shielded cable/independent cable) connector
SBU-LEDB wire (FFC) connector
3. The whiteboard (exposed glass) is dirty or defective
Check for dirt or defects on the whiteboard connected to the exposure glass.
If the exposure glass becomes dirty or defective, please replace it.
4. If the ADF guide plate (white roller) is defective, replace the ADF guide plate.
5. Poor mirror and optical device
Check for dirt or defects on the first scanning frame (mirror)/second scanning frame (mirror).
If the scanning frame is dirty or defective, please replace it.
6. Replace the LED boards on both sides.
Link: https://pan.baidu.com/s/1RR5bUeF4TDa7WQeZcE2QYw