Epson projector CB-L23000U,CB-L25000U,CB-L30000U Chinese repair manual

Come back soon. 347 0

EB-L25000U/EB-L30000U/L30002U/Pro
L30000U/L30002U/CB-L30000U
This section mainly introduces the use of error codes and equipment codes displayed on the AS (after-sales service) menu and IPS tools to identify faulty components for troubleshooting and perform corresponding repairs. If the device code can be identified through the AS menu or IPS tool, please search for the specific problematic component from the table below.
When the faulty parts can be identified, the blue letter parts with reference pages in the table below can be replaced in a shorter way than regular disassembly procedures.
Dangerous Distance (HD)
To protect untrained end-users (such as cinema visitors and spectators), installation should comply with the following installation requirements:
The operator should control the channel for entering the beam within a dangerous distance, or install the product at a height that prevents the audience's eyes from entering the dangerous distance. At any point below 2.0 meters (SH) above any horizontal plane where personnel other than operators, performers, or employees are allowed to stand, or at any point with a horizontal distance of less than 1.0 meter (SH) from any place where personnel are allowed to stand, the radiation level shall not exceed the limit. In the case of reasonably foreseeable unrestricted behavior, the minimum spacing height should be greater than or equal to 3.0 meters to prevent potential exposure, such as in HD where one person sits on the shoulder of another.
These values are minimum values based on the guidelines provided in Section 6.6.5 of IEC 62471-5:2015.
Installation personnel must be aware of the risks and take protective measures based on the hazardous distance indicated on the labels and user information. The installation method, isolation height, barrier, detection system or other applicable control measures should prevent the eyes from being exposed to radiation within a dangerous distance.
For example, if the danger distance is greater than 1m, the projector should be positioned and installed according to the "fixed installation of projector" parameters to prevent the projection beam from entering uncontrolled areas where people may be present, thereby creating a safe distance that will not extend to the audience area, unless the beam is at least 2.0 meters above the floor. In environments where unrestricted behavior can be reasonably foreseen, the minimum spacing height should be greater than or equal to 3.0 meters to prevent potential exposure, such as in HD where one person sits on the shoulder of another. By installing the image projector on the ceiling or using physical barriers, a sufficiently large separation height can be achieved.
The above restrictions do not apply to laser illuminated projectors (LIPs) installed in the US market. For installations outside of cinemas, they should be installed at a vertical height above the floor, and the bottom of the danger zone should not be lower than 3 meters above the floor. The horizontal clearance of the danger zone should be 2.5 meters. If it is possible for someone to enter the danger zone horizontally, a restricted area with obstacles should be set up when conditions permit. If there is a possibility of people entering in an unsupervised environment, horizontal or vertical spacing should be increased to prevent exposure to the RG3 hazardous area.
Install one or more easily accessible control devices to immediately terminate the LIP projection lamp. The power input of the projector is considered a reliable disconnect device. When you need to turn off the projector, please disconnect the power cord on the projector side.
If it is not possible to access the power input of the projector (such as truss installation), an easily accessible power socket should be installed near the projector, or an easily accessible universal disconnect device should be installed in the fixed wiring. In addition, press the shutter button on the projector control panel or remote control to turn off the projection lights.
Link: https://pan.baidu.com/s/1xu7ec9j1pqLG9w0OW0cEOQ

Tags: #L23000U #L25000U #L30000U #Projector