Xerox Copier Controller Controller-FIP Chinese Repair Manual Version 1.5
Xerox copier controller FIP English maintenance manual version 1.7
OF-32 [No error code] ([Not restored from power-saving state] The state in which the fault occurred, or the state in which the fault can be reproduced.)
Confirm the detailed steps for collecting faults from customers during the task.
In which mode does the malfunction occur? (Copy/Scan/Print/Fax)
2. Which type of task encountered a malfunction during execution?
3. Confirm the settings of the assignment from the UI.
4. Confirm whether the hard drive is temporarily stored.
5. In addition, collect as much reproducible fault information as possible.
When accessing, the state where the fault occurred or the fault can be reproduced without recovering from the power-saving state. (Except for situations where the power is turned off and then turned on but still cannot start normally)
Steps
1. Confirm that the power LED of the UI is on.
2. [Only applicable to ESS hardware diagnostic models] Perform ESS hardware diagnostics. [Only applicable to ESS hardware diagnostic models] Perform ESS hardware diagnostics.
3. If the fault occurs in a certain state or a reproducible state, collect logs.
1.4.1 Log Collection (FB/FBAP)
1.4.1 Log Collection (WW)
When ping, confirm the recovery status through the UI button.
4. Check the status of the ESS Status LED next to the connection cable of the ESS PWB.
(Refer to BSD 25.4 ESS STATION LED.)
5. [Only applicable to IOT (AST: Analysis Support Tool) diagnostic configuration models] Start the machine normally and perform IOT diagnosis. (Refer to IOT diagnostic steps)
6. [Only applicable to IIT diagnostic configuration models] Perform IIT diagnosis.
7. If in step 3 Unable to retrieve logs, collect logs.
If the software is not the latest version, download the latest version of the software. (Refer to 1.5.1 Software Download)
If the fault persists, perform the following steps. Confirm the installation status of the connector cables between ESS PWB and (IISS PWB, IOT PWB, Monza PWB), correctly install them, and perform the same operation as when the fault occurred.
10. Pull out/insert ESS RAM DIMM and perform the same operation as when the fault occurred.
11. Pull out/insert the HDD connector and perform the same operation as when the fault occurred.
12. Replace the RAM DIMM and perform the same operation as when the fault occurred.
13. Replace the HDD and perform the same operation as when the failure occurred.
14. Replace the ESS PWB and perform the same operation as when the malfunction occurred.
If the ESS PWB cannot be repaired after replacement, restore the original PWB and contact the support department for instructions.
Collect logs as needed in order to submit them to the support department.