Canon 6575,6565,6555 upgrade firmware program

Visitor 320 0
imageRUNNER ADVANCE 6575
imageRUNNER ADVANCE 6565
imageRUNNER ADVANCE 6555
MN-CONT
64.19
DC-CON
49.01
R-CON(1PASS)
41.01
PANEL (no NFC KIT)
02.22
PANEL (including NFC KIT)
02.23
G3FAX (FAX1, FAX2/3/4)_BOOT
21.21
G3FAX (FAX1, FAX2/3/4)_MAIN
21.21
TSP
01.50
Staple Finisher-V1,V2/Booklet Finisher-V1,V2_SORTER
55.04
Staple Finisher-V1,V2/Booklet Finisher-V1,V2_SORT-SLV
40.01
Booklet Finisher-V1,V2_SDL-STCH
36.01
2/3 Hole, 2/4 Hole, 4 Hole Puncher Unit-A1_PUNCH
15.01
Modifications for previous versions
* Consult the product planning department with detailed new features/function extensions.
* Please refer to the service manual for newly added service modes/modified parameters
1. Firmware upgrade to MN-CONT Ver. Modifications when the version is 64.19.
1-1.[Countermeasures for on-site problems] Customer requirements, increase fax function support options in maintenance mode.
In the maintenance mode, the address notification function is added. IFAX communication is transferred to the login address of the mail user through the mail command.
Setting method:
1) Set the fax service mode (FAX>SSSW>SW50>bit3 = "1")
2) Set maintenance mode (LV2):COPIER>OPTION>CUSTOM2> SP-B42:0 default, 1 open
-If the value is 0, and has not been logged in, and the email address of the logged-in user has not been set, the value is CUSTOM2/SP-B42
Set the email address of the device;
-When this value is 1, it means that the address notified by the MAIL FROM command of IFAX communication is set to the mail address of the login user.
1-2. [Countermeasure on-site problem] An error in which the device stays in the "waiting to print" state when printing a specific PDF or PowerPoint document.
1-3. [Countermeasure Field Problem] When IFAX is forwarded to the designated LBP device, the problem that the split and output file goes wrong has been modified.
1-4. [Countermeasure Field Problem] When the automatic clearing time is equal to or greater than the automatic sleep time, the user authentication display interface will become the main interface
Error, and some buttons will turn gray and cannot be used.
1-5. [Countermeasure Field Problem] The problem of "#919" error code when printing with PS driver under uniFLOW server has been modified.
1-6. [Countermeasure Field Problem] The problem that SMB data cannot be analyzed during SMB transmission and reception and no error is reported in the transmission state has been modified.
2. Operation panel (without NFC) upgrade to Ver. Modifications at the time of 02.22.
2-1. [Modify Specifications] Support new control panel CPU.
3. Upgrade the operation panel (including NFC) to Ver. Modifications at the time of 02.23.
3-1. [Modify specifications] Support new control panel CPU.
Meap Specification Version:
Service Support Tool:
To update the firmware, use the latest version of the Service Support Tool (latest Ver.4.81 or newer).
Link: https://pan.baidu.com/s/1coGwAqjXW36AG7RCXflmLA
Extraction code: p7hj