Canon iR 2206i iR 2206ADiR 2206N iR 2206L Repair Manual - Chinese Version

Visitor 340 0



E000-0000- Insufficient temperature rise of the fixing component during startup temperature control
Detecting that the fixing component does not reach a constant temperature within the specified time when starting temperature control.
Countermeasure 1 Complete the following steps to clear the error: COPIER>MOTION>CLEAR>ERR; Then turn off and then turn on the power again.
2. Check the plug between the fixing component and the controller circuit board (PCB1).
3. Replace the fixing component.
4. Replace the controller circuit board (PCB1).
E001-0000- Abnormal temperature rise of fixing component (main thermistor)
The reading of the main thermistor is 240 degrees Celsius or higher.
Countermeasure 1 Complete the following steps to clear the error: COPIER>MOTION>CLEAR>ERR; Then turn off and then turn on the power again.
2. Check the plug between the fixing component and the controller circuit board (PCB1).
3. Replace the fixing component.
4. Replace the controller circuit board (PCB1).
E001-0001-- Abnormal temperature rise of fixing component (secondary thermistor)
The reading of the secondary thermistor is 295 degrees Celsius or higher.
Countermeasure 1 Complete the following steps to clear the error: COPIER>MOTION>CLEAR>ERR; Then turn off and then turn on the power again.
2. Check the plug between the fixing component and the controller circuit board (PCB1).
3. Replace the fixing component.
4. Replace the controller circuit board (PCB1).
E002-0000- Insufficient temperature rise of the fixing component during printing temperature control
Detecting that the fixing component does not reach a constant temperature within the specified time during printing temperature control.
Countermeasure 1 Complete the following steps to clear the error: COPIER>MOTION>CLEAR>ERR; Then turn off and then turn on the power again.
2. Check the plug between the fixing component and the controller circuit board (PCB1).
3. Replace the fixing component.
4. Replace the controller circuit board (PCB1).
E003-0000- Low fixing temperature detected after standby (main thermistor)
Detect that the reading of the main thermistor is below the specified temperature.
Countermeasure 1 Complete the following steps to clear the error: COPIER>MOTION>CLEAR>ERR; Then turn off and then turn on the power again.
2. Check the plug between the fixing component and the controller circuit board (PCB1).
3. Replace the fixing component.
4. Replace the controller circuit board (PCB1).
E003-0001- Low fixing temperature detected after standby (secondary thermistor)
Detect that the reading of the secondary thermistor is below the specified temperature.
Countermeasure 1 Complete the following steps to clear the error: COPIER>MOTION>CLEAR>ERR; Then turn off and then turn on the power again.
2. Check the plug between the fixing component and the controller circuit board (PCB1).
3. Replace the fixing component.
4. Replace the controller circuit board (PCB1).
Link: https://pan.baidu.com/s/1SqnJOoRu-H5WM_rTC5jDjQ
Extraction code: 3j81

Tags: #Canon #IR 2260I

Leave a comment