Ricoh MP CW2200SP,CW2201SP,W6700,W8140,W7100 Engineering Machine Maintenance Manual


SC200-00 suction cap in-situ sensor error
The sliding sensor of the maintenance unit did not detect the suction cover and scraper components in situ.
• Loose, damaged or poor connection of in-situ sensors
Paper or other obstacles hinder the movement of the mechanism
• Poor in-situ sensor
SC201-01 Printing Head Cover In Situ Sensor Error
The cover sensor inside the maintenance unit did not detect the left base at the up and down position (original position).
• Loose, damaged or poor connection of in-situ sensors
Paper or other obstacles hinder the movement of the mechanism
• Poor in-situ sensor
SC201-02 cleaner unit slider sensor error
The slider sensor at the rear of the maintenance unit failed to detect whether the cleaner unit is in the forward or backward position (original position). The left base, suction cover, rubber scraper, and scraper form the maintenance and cleaning unit.
• Loose, damaged or poor connection of in-situ sensors
Paper or other obstacles hinder the operation of the motor
• Poor in-situ sensor
• Motor malfunction
SC202 ink level detection lever position error
There is one of the following situations:
When clearing the air, one or more touch levers cannot be detected, so the operation cannot continue.
When the maintenance pump attempts to apply negative pressure on the ink tank of the print head, it cannot detect that the touch rod is in the designated position after applying pressure.
After filling and checking the tactile sensor, OCFS cannot detect the tactile sensor.
Ricoh MP W7100SP W8140SP Engineering Machine Chinese Maintenance Manual Link: https://pan.baidu.com/s/1RB1QwkSRUhuYMrIW4WnJzQ