Konica Minolta 4700P_4000P Printer Repair Manual

Visitor 282 0


Double sided device maintenance and inspection
Is there a solution
Step 1
1. Remove the back cover. Please refer to the disassembly of the rear door and cover.
2. Check if the heavy drive roller is worn or damaged.
Is there no wear or damage?
Go to step 2. Replace the heavy drive components. Please refer to Heavy
Disassembly of drive components.
Step 2
1. Remove the left cover. Please refer to the disassembly of the left cover.
2. Execute POR to enter the "Diagnosis" menu, and then perform double-sided paper feeding test
Try:
Diagnostic menu>Print test>Double sided paper feeding 1
3. Check if the reversing electromagnet is operating normally.
Is it working properly?
Go to step 3. Replace the reversing electromagnet. Please refer to
Disassemble the reversing electromagnet.
Step 3
1. Remove the paper feeding box.
2. Under the printer, check the double-sided gear assembly and double-sided linkage
Whether the device is worn and damaged.
Is there no wear and damage?
Go to step 4. Replace the double-sided gear assembly. Please
Refer to the disassembly of the double-sided gear assembly
Unload.
Step 4
Under the printer, check for wear and tear on the double-sided printer, transfer belt, and rollers
Damaged.
Is there no wear and damage?
Go to step 5. Replace the double-sided device. Please refer to double-sided
Dismantling of equipment.
Link: https://pan.baidu.com/s/1JD_VvR965WDoWQbjEK7O7Q Password: lpdg

Tags: #Maintenance Manual #Ke Mei #4700P

Leave a comment