Canon black and white machine iC MF6140dn 6160dw MF5900 MF6100 D1300 repair manual

Visitor 284 0
Canon black and white machine iC MF6140dn 6160dw MF5900 MF6100 D1300 repair manual


Fault detection
When the following conditions are encountered, the DC controller determines that the fixing assembly is faulty, invalidates the fixing heater control signal, releases the relay to interrupt the power supply to the fixing heater and notifies the formatter of the fault status:
1) Startup failure
• If the detected temperature of the thermistor during waiting is maintained at the specified temperature or higher for the specified period of heater activation.
• If the detected temperature of the thermistor during printing is maintained at the specified temperature or lower for the specified period under the heater temperature control.
• If the detected temperature of the thermistor does not reach the target temperature within the specified period under the heater temperature control during the initial rotation.
2) Abnormal low temperature
• If the detected temperature of the thermistor is maintained at the specified temperature or lower for a specified period under heater temperature control.
3) Abnormally high temperature
• If the detected temperature of the main thermistor remains the specified temperature or higher during the specified period.
4) Drive circuit fault
• If the specified frequency of the frequency signal is not detected within the specified period after the printer is turned on.
Link: https://pan.baidu.com/s/1FQkaVrTUjX-XFDrGHi4fhg
Extraction code: 3trl

Tags: #6140 #6160 #6100 #1300