Xerox DocuPrint M288 z / M288 dw Chinese repair manual

Visitor 309 0
Xerox DocuPrint M288 z / M288 dw Chinese repair manual
Error code 0501
The Fuser unit's Cen ter thermistor did not reach the specified temperature within the specified time.
Error code 0502
The Fuser unit's Center thermistor did not reach the specified temperature within the specified time after the normal heating to a specific level.
Error code 0503
The Cen ter thermistor of the Fuser unit detects that the temperature exceeds the specified value.
Error code 0504
After normal heating of Heat un it, the center thermistor of the Fuser unit detects that the temperature is lower than the specified value.
Error code 0505
The Cen ter thermistor of the Fuser unit detects that the temperature has exceeded the specified value within the specified time.
Error code 0506
The Fuser unit's Center thermistor detects that the temperature has far exceeded the specified value for the specified time.
Error code 0508
When the Fuser unit hea t er was opened, the tip temperature did not rise by 1°C.
Error Code 050A
The hardware detected a temperature error via Fuser un it's Center thermistor or Side thermistor.
Error Code 050B
When the Center thermistor temperature of Fuser uni t is lower than the idle temperature, Qin de thermistor detects that the temperature is higher than the specified temperature.
Error Code 050C
When the center thermistor temperature of Fuser uni t is higher than the idle temperature, the thermistor detects that the temperature is lower than the specified temperature.

Download address: https://www.16qiang.cn/view-9757-1-1

Tags: #M248b #m288 #m235dw #m275